AKCP In-Line Power Meter (ILPM)

Power Monitoring and Switching

AKCP In-Line Power Meter (ILPM)
7908_34393.png
7908_34394.png
7908_34395.jpg
7908_34396.jpg
  • EigenschaftenEigenschaften
  • BeschreibungBeschreibung
  • Weitere InformationenWeitere Informationen
  • PDFPDF
  • Monitor and switch an individual Appliance
  • Monitor complete Power Strip, turn a power strip into a smart PDU
  • Graph power, voltage, current parameters.
  • Receive alerts if electrical parameters exceed your pre-defined thresholds
  • Shutdown power automatically if over voltage, over current, or smoke detected
  • Optional Thermal Map for use in a Rack+ system
  • Optional Smoke Detector for Patent Pending Fire Suppression
  • Optional LCD Display
  • Bare end wires as standard or optional plug
  • 100-250 AVAC Input

The power meter goes between the electrical source and the power strip, or individual appliance, monitoring the voltage (V), current (A) and Kilowat Hours (kWh) being consumed with billable grade accuracy. Remotely switch devices on and off with optional relay. Relays are Bi-Stable Latched relay, which retains it?s state regardless of whether it is receiving power or not.


Inline Power Meter is essential for:
  • Checking how close you are to tripping your circuit breaker
  • Ensure sufficient power overhead before adding new equipment to a circuit
  • Billing individual clients in co-located services
  • Monitoring up to 16 In-Line Power Meters from a single sensorProbe+



Advantages

Removing the controller from your power strip allows you to use a low cost basic power strip. This gives several advantages, in addition to the cost savings.
  • A single IP address to monitor multiple cabinets.
  • Hot swappable controller, no downtime to cabinets if servicing is needed
  • More space for outlets on your power strip as the controller is moved out of the 0U space
  • As future needs increase, just change the power strip no need for new controller and power meter.

ProdGrafik
ILPM - Technical Specification

Measurements
Power Rating Input Voltage rating :
- 1 phase
- 100V~250V AC
Current Rating :
- 16A
- 32A
Power Measurements - Voltage (V)
- Current (A)
- Active Power (kW)
- Total Active Energy (kWh)
- Leakage current (A)
- Power Factor
Environment monitoring Optional Cabinet Thermal Map (-CTM or -CTHM)
- Temperature sensor
*range -40°C to +75°C
- Humidity sensor
* 0 to 100% Relative humidity
Control
Switching Relay Latched Relay
Contacts rating : 40 Amp
Mechanical Life : 1 10^7 times
Electrical Life : 3 10^4 times
Class B
Status Indication LED indication for power
LED Relay status (with optional relay)
Inputs 1x sensor RJ45 Port
Hardwired with following plugs :
- IEC 60320 C20
- IEC 60320 C14
- Nema 5-15P
- Nema 5-20P
- Nema 5-30P
- Nema L5-15P
- Nema L5-20P
- Nema L5-30P
- UK BS
- Shuko CEE 7/7 plug
- IEC60309 2P+E blue
Outputs Outlet types :
- IEC 60320 C13
- IEC 60320 C19
- Nema 5-15R
- Nema 5-20R
- Nema 5-30R
- Nema L5-15R
- Nema L5-20R
- Nema L5-30R
- UK BS1363
- Shuko CEE 7/3 Socket
- IEC 60309 2P+E Blue
Interface
Communications cable RJ-45 jack to sensor using UTP CAT5e/6 cable
Power source Powered by the sensorProbe+ familiy units. No additional power needed
Power Consumption Typical 800 mWatt, 160 mA
Peak 1.75 Watt, 350 mA
Maximum Cable Length      Run length is 32 feet (10 meters) with approved low capacitance shielded cable or UTP
Dimensions 170 x 85 x 52 mm
Mounting Keyhole mounting
Components Manufactured using highly integrated, low power surface mount technology to ensure long term reliability.    
Operating Environment Temperature : Min. -35° C - Max.80° C
Humidity: Min. 20% - Max. 80% (Non-Condensing)
MTBF 1,400,000 Hours based on field experience with sensorProbe units.
Important Note sensorProbe+ units auto detects the presence of the ILPM sensor
- The ILPM sensor is only compatible with the sensorProbe+ platform units.
- When plugging the first time or after upgrading a sensorProbe+ unit, the sensor's firmware might be
upgraded by the unit and not be available right away.
- On the sensorProbeX+, the sensor can be used only on the main module sensor ports
Sensor count ILPM : 5
ILPM-LR : 6
-CTM : +9
-CTHM : +11



Ordering Information

In-Line Power Meter
ILPM-32A "Inline power Meter 32A
25cm power in / out cable with bare ends"
ILPM-16A "Inline power Meter 16A
25cm power in / out cable with bare ends"
In-Line Power Meter Options
Relays
LR Latched relay
Thermal Maps
ILPM-CTM Cabinet Thermal Map - Temperature only
ILPM-CTHM      Cabinet Thermal Map - Temperature & Humidity     
10A Connections
C13 IEC C13 (Power Out)
C13L IEC C13 Locking (Power Out)
C14 IEC C14 (Power In)
13A Connections
UKP UK Plug (Power In)
15A Connections
AUS AUS (Power In)
5-15R Nema 5-15R (Power Out)
5-15P Nema 5-15P (Power In)
16A Connections
EURP EUR (Power In)
C19 C19 (Power Out)
C19L C19 Locking (Power Out)
C20 C20 (Power In)
2PEP IEC 2P+E (Power In)
2PEO IEC 2P+E (Power Out)
20A Connections
5-20R Nema 5-20R (Power Out)
L6-20P Nema L6-20P (Power In)
5-20P Nema 5-20P (Power In)
30A Connections
5-30P Nema 5-30P (Power In)
L6-30P Nema L6-30P (Power In)
32A Connections
2PEP-32 IEC 2P+E (220V Power In)
2PEO-32 IEC 2P+E (220V Power Out)

Kunden, die diesen Artikel gesehen haben, sahen auch
Alle Cookies akzeptieren Ablehnen Konfigurieren

Diese Website verwendet Cookies, um eine bestmögliche Erfahrung bieten zu können. Mehr erfahren.