Raritan PX3-1440R
Monitored rack power distribution unit
(2U [horizontal], 3.7kVA, 20 outlets)
Monitored rack power distribution unit (2U [horizontal], 3.7kVA, 20 outlets).
INPUT:
230v, 16a - IEC 60309 2P+E 6h 16A plug (2P3W);
OUTPUT:
20@ C13 outlets;
FEATURES:
Billing-Grade (+/- 1%) Energy Metering [kW, kVA, V, A, Power Factor] - per inlet;
Color, matrix LCD display : Voltage, current, or active power (per line);
Alarms;
Configuration information (name, ratings, IP / Networking information).
Auto-flip orientation.;
400MHz processor, 16MB NOR Flash, and 64MB SDRAM;
(10/100) Ethernet portRemote network monitoring via HTML, JSON-RPC, SSH, Telnet, MODBUS/TCP, and SNMPv3.
Environmental monitoring [temp/humidity] capable of up to 32 sensors.
Individual outlet numbers labeled on chassis.
Automated deployment via TFTP, DHCP/PXE, SSH(CLI), or USB Flash Drives.
WiFi Capable.
USB Webcam Capable.
iPad/iPhone/Android App.
Max Dimensions 440mm x 133mm x 88mm (17.3in x 5.2in x 3.5in).
Max Weight 3 kg.
Maximum ambient temperature 60C at full load.
Features
- Energy Metering
Voltage (V), Current (A), Active Power (kW), Real Power (kVA), Energy (kWh), Power Factor
Metering Accuracy
ISO/IEC 62053-21 1%
Remote Outlet Switching
No
Metering per input line
Yes for all models
Metering per Branch Circuit Breaker
No
Environmental Sensor Ready
Yes
Compatible Sensors
Temperature, Humidity, Air Flow, Differential Pressure, Water Leak, and Contact Closure.
Cascading
Yes, Max 16 PDUs can be daisy chained using a USB connection.
Note: Firmware version 3.3.10 or above is required.
Networking
10/100/1000 BaseT Ethernet.
Optional WiFi (802.11a/b/g/n).
Onboard Display
Color, matrix LCD display : Voltage, current, or active power (per line);
Alarms;
Configuration information (name, ratings, IP / Networking information).
Auto-flip orientation.
Specifications
- Input
- Input Plug
IEC 60309 2P+E 6h 16A (2P3W)
Nominal Voltage
230V
Maximum Input Current
16A
Rated Input Current
16A
Power Capacity
3.7kVA
Cord Length
3m
Output
- Nominal Voltage
230V
Receptacles (Output Connections)
(20) IEC320 C13
Overload Protection
NA
Physical
- Dimensions (WxDxH)
17.3in x 5.2in x 3.5in; 440mm x 133mm x 88mm
Unit Weight
3 kg
Shipping Weight
6.5 kg
Shipping Dimensions
468mm x 180mm x 554mm
Mounting
Tool-less Button Mount
Environmental
- Operating Temperature/Environment
60 C
Operating Relative Humidity
85%
Operating Elevation
0-10000ft
Conformance
- Regulatory Approvals
CE