PERLE IDS-105GPP

Industrial Gigabit PoE Switch 5 to 7 port Compact DIN Rail PoE Switch

PERLE IDS-105GPP
4710_29978.png
4710_29979.gif
4710_29980.gif
4710_29981.gif
  • EigenschaftenEigenschaften
  • BeschreibungBeschreibung
  • Weitere InformationenWeitere Informationen
  • PDFPDF
  • 5 port 10/100/1000Base-T ( RJ45 )
  • 5 port 10/100/1000Base-T ( RJ45 ) with 1 or 2 Gigabit fiber ports (SC/ST/SFP)
  • 4 PoE/PoE+ PSE capable ports, fully compliant to IEEE 802.3af/at
  • Hazardous Location and Industrial Control Equipment Certification
  • Corrosion resistant IP30 aluminum case
  • Redundant dual power input 24/48 VDC
  • Overload current and reverse polarity protection
  • Industrial operating temperature support up to -40 to 75°C
Perle Industrial-grade Ethernet Switches are designed to stand up to extreme temperatures, surges, vibrations, and shocks found in industrial automation, government, military, oil and gas, mining and outdoor applications.

In addition, these PoE Switches are classified as Power Sourcing Equipment (PSE). While using standard UTP cables that carry Ethernet data, the IDS-108FPP have 4 ports that also provide up to 30 watts of power to Powered Devices (PDs) such as wireless access points, Voice over IP phones and IP cameras. Learn more about PoE.

The IDS-105GPP is a 5 to 7 port Industrial Gigabit Ethernet switch providing advanced performance enabling real-time deterministic network operation. It requires no configuration and will operate instantly as soon as you power it up.

IDS-105G are rugged fan-less switches that are hardened to provide superior reliability in 0 to 60°C, or harsh extended operating temperatures from -40 to 75°C. They come in a variety of models with 5 copper ports, 5 copper ports plus 1 fiber port or 5 copper ports plus 2 fiber ports.

Perle has been designing industrial hardware for serial ModBus and Profinet to Ethernet conversion environments for over 35 years and have used this expertise to design the toughest Ethernet switches on the market. Don’t trust your critical communications to commercial switch products. Perle Industrial Ethernet switches give you proven assurance that your system will keep running for years to come.


IDS-105GPP Industrial Gigabit PoE Switch Features

Rugged design for harsh environments
  • Corrosion resistant IP30 aluminum case
  • UL508A Industrial Control Equipment Safety certified
  • Hazardous locations - Class1/Div2, ATEX Class1/Zone2


Reliable operation
  • Fan-less, no moving parts
  • Dual power input. Connect to separate power sources for redundancy.
    • Reverse polarity protection
    • Overload current protection
  • Handles vibration and shock conditions found in industrial environments


Real-time Ethernet performance
  • Fast wire-speed , store and forward switching, non-blocking architecture
  • Auto-sensing for speed and duplex
  • Auto-mdi/mdix-crossover works with straight and crossover cables


PoE and PoE+ ( on 4 ports )
  • Up to 30 Watts per port driving up to four class 4 ( IEEE 802.3at Type 2 ) PDs


Input Voltage Booster
  • Voltage boost technology supports 24V power sources ensuring that a full and proper PSE voltage is provided across all PoE ports


Jumbo Frames
  • Supports Jumbo frames up to 10 KB


Energy Efficient Ethernet ( EEE )
  • Energy Efficient Ethernet (EEE) as per 802.3az. This provides power savings during idle network activity.




IDS-105GPP Industrial Switch Power over Ethernet ( PoE )Diagram
ProdGrafik

Power

    Dual Power Input
    Both inputs draw power simultaneously. If one power source fails, the other live source can, acting as a backup, supply enough power to meet the operational needs of the switch.
    Flexible input voltage range : 24/48 VDC Nominal. ( 18 to 57 VDC)

    Input Voltage Booster
    Voltage boost technology supports 24V industrial power sources ensuring that a full and proper PSE voltage is available across all PoE ports

    Power Connector
    4-Pin Removable Terminal Block.
    Grounding screw on metal chassis

    Maximum Current Consumption @24 vDC
    .27 Amps (No PoE PDs attached)
    5.5 Amps (4 x PoE+)

    Maximum Power Consumption @24 vDC
    6 Watts (No PoE PDs attached)
    132 Watts (4 x 30 Watts PoE+)

    Overload Current Protection
    Reset-able fuse provides overload current protection

    Reverse polarity protection
    Protection is provided should inputs be reversed.



Access Ports

    RJ45
    5 shielded RJ45 ports for 10/100/1000Base-T up to 100 meters ( 328 ft ). 4 of these ports are PoE PSE capable
    Auto-negotiation
    Auto-MDI/MDIX-crossover for use with either crossover over straight-through cable types
    Ethernet isolation 1500 V

    PoE
    4 PoE/PoE+ ports
    Up to 30 Watts per port ( @ switch RJ45 ) driving up to four class 4 ( IEEE 802.3at Type 2 ) PDs

    Small Form Factor Pluggable ( SFP ) slot(s)
    1 or 2 empty SFP slot models for 1000Base-X SFP modules supplied by Perle, Cisco or other manufacturers of MSA compliant SFPs

    Fixed Fiber port
    Fixed fiber port models
    Duplex SC or ST connector
    • Multimode 50/125 or 62.5/125 micron fiber cable
    • Single mode 9/125 micron fiber cable
    Simplex ( BIDI, single strand ) SC connector
    • Multimode 50/125 or 62.5/125 micron fiber cable
    • Single mode 9/125 micron fiber cable
    PC and UPC type patch cords supported.



Switch Properties
    Standards
    • IEEE 802.3 for 10Base-T
    • IEEE 802.3u for 100Base-TX and 100Base-FX
    • IEEE 802.3ab for 1000Base-T
    • Energy Efficient Ethernet (EEE) as per 802.3az.
    • IEEE 802.3x for Flow Control
    • IEEE 802.3af Power Over Ethernet
    • IEEE 802.3at Power Over Ethernet

    Processing Type
    Store and Forward, non-blocking architecture

    MAC Address Table Size
    8K

    Packet Buffer Memory
    1 Mbit

    Jumbo Frame Size
    10 KB



Indicators

    P1
    This green LED is turned on when power is applied to the power #1 input

    P2
    This green LED is turned on when power is applied to the power #2 input

    RJ45 Ethernet
    These integrated colored LEDs indicate link, activity and speed for each port.

    Fiber Link
    Fiber link LED indicates Link and Data Activity



Environmental Specifications

    Operating Temperature Ranges
    Standard temperature models : 0° C to 60° C (32° F to 140° F).
    Industrial extended temperature models : -40° C to 75° C ( -40 F to 167° F )

    Storage Temperature Range
    Minimum range of -25° C to 70° C (-13° F to 158° F). -40 C to 85° C (-40 F to 185° F) for industrial extended temperature models

    Operating Humidity Range
    5% to 90% non-condensing

    Storage Humidity Range
    5% to 95% non-condensing

    Operating Altitude
    Up to 3,048 meters (10,000 feet)

    Chassis
    Aluminum with an IP30 ingress protection rating

    Din Rail Mountable
    DIN Rail attachment included. Mounts to standard 35 mm DIN rail in accordance with DIN EN 60175.
    Removable to accommodate optional Panel/Wall mount kit

    Maximum Heat Output
    178 BTU/Hr

    MTBF
    648,530 hours (without fiber module)
    492,890 hours (with fixed fiber module)
    472,435 hours (with 1 SFP slot)
    371,779 hours (with 2 SFP slots)
    MTBF Calculation model based on MIL-HDBK-217-FN2 @ 30 °C



Product Weight and Dimensions

    Weight
    0.37 Kg, 0.82 lbs

    Dimensions
    35.5 x 111 x 138 mm, 1.39 x 4.37 x 5.43 inches



Packaging

    Shipping Weight
    0.52 Kg, 1.15 lbs

    Shipping Dimensions
    170 x 260 x 70 mm, 6.69 x 10.24 x 2.76 inches

    Contents Shipped
    Industrial Ethernet Switch with DIN Rail attachment
    Terminal block
    Installation guide



Standards and Certifications

    Safety
    UL 60950-1
    CSA C22.2 No. 60950-1
    IEC 60950-1:2005+A1:2009 and
    EN 60950-1:2006+A11:2009+A1:2010+A12:2011
    CE Mark
    UL508 ( Industrial )

    EMC Emissions
    FCC 47 Part 15 Class A
    ICES-0003
    CISPR 22:2008/EN55022:2010 (Class A)
    EN61000-6-4

    EMC Immunity
    CISPR 24:2010/EN 55024:2010
    IEC/EN 61000-4-2 (ESD) : Contact discharge +/- 4kV, Air Discharge +/- 8kV
    IEC/EN 61000-4-3 (RS) : 80 MHz to 2.7 Ghz ; 10V/m, 800 MHz to 1000 MHz; 20V/m
    IEC/EN 61000-4-4 (EFT) : DC power line +/- 2 kV, Data Line +/- 1kV
    IEC/EN 61000-4-5 (Surge) : DC power line, Line/Line +/- 0.5kV, Line/Earth +/- 0.5kV, Data Line line/earth +/- 1kV
    IEC/EN 61000-4-6 (CS) : 150kHz to 80 MHz; 10V
    IEC/EN 61000-4-8 : 30A/m
    IEC/EN 61000-6-2 ( General Immunity in Industrial Environments )

    Industrial Safety
    UL508 (Safety standard for Industrial Control Equipment )
    CSA C22.2 No. 142

    Hazardous Locations ( Hazloc )
    ANSI/ISA 12.12.01, Class I Division 2 Groups A-D ( formerly known as UL 1604 )
    CSA C22.2 No. 213
    ATEX Class I Zone 2, EN 60079-0,15

    Laser Safety
    EN 60825-1:2007
    Fiber optic transmitters on this device meet Class 1 Laser safety requirements per IEC-60825 FDA/CDRH standards and comply with 21CFR1040.10 and 21CFR1040.11.

    Environmental
    Reach, RoHS and WEEE Compliant

    Other
    ECCN: 5A991A
    HTSUS Number: 8517.62.0050




Ordering Information




Operating Temperature (Std) = 0° C to 60° C (32° F to 140° F).
All Models have 5 x 10/100/1000Base-T ( RJ45 ) Connectors
 

Model

Choose your Fiber Connection from the table below
1000Base-X Duplex Fiber

Fiber
Connector

Transmit
(dBm)

Receive
(dBm)

Power
Budget
(dB)

Wavelength
(nm)

Fiber
Type

Operating
Distance

Min

Max

Min

Max

IDS-105GPP No Fiber connection
IDS-105GPP-SFP 1 x SFP slot (empty) Fiber specifications are dependent upon the choice of SFP used
IDS-105GPP-DSFP 2 x SFP slot (empty) Fiber specifications are dependent upon the choice of SFP used
IDS-105GPP-M2SC05 1 x Duplex SC -9.5 -4.0 -17.0 -3.0 7.5 850 MMF 550 m
(1,804 ft)
IDS-105GPP-M2ST05 1 x Duplex ST -9.5 -4.0 -17.0 -3.0 7.5 850 MMF 550 m
(1,804 ft)
IDS-105GPP-M2SC2 1 x Duplex SC -6.0 0.0 -17.0 0.0 11.0 1310 MMF 2 km
(1.2 mi)
IDS-105GPP-M2ST2 1 x Duplex ST -6.0 0.0 -17.0 0.0 11.0 1310 MMF 2 km
(1.2 mi)
IDS-105GPP-S2SC10 1 x Duplex SC -9.5 -3.0 -20.0 -3.0 10.5 1310 SMF 10 km
(6.2 mi)
IDS-105GPP-S2ST10 1 x Duplex ST -9.5 -3.0 -20.0 -3.0 10.5 1310 SMF 10 km
(6.2 mi)
IDS-105GPP-S2SC40 1 x Duplex SC -2.0 2.0 -23.0 -3.0 21.0 1310 SMF 40 km
(24.9 mi)
IDS-105GPP-S2ST40 1 x Duplex ST -2.0 2.0 -23.0 -3.0 21.0 1310 SMF 40 km
(24.9 mi)
IDS-105GPP-S2SC70 1 x Duplex SC -2.0 5.0 -23.0 -3.0 21.0 1550 SMF 70 km
(43 mi)
IDS-105GPP-S2ST70 1 x Duplex ST -2.0 5.0 -23.0 -3.0 21.0 1550 SMF 70 km
(43 mi)
IDS-105GPP-S2SC120 1 x Duplex SC 0.0 5.0 -32.0 -9.0 32.0 1550 SMF 120 km
(74.6 mi)
IDS-105GPP-S2ST120 1 x Duplex ST 0.0 5.0 -32.0 -9.0 32.0 1550 SMF 120 km
(74.6 mi)
IDS-105GPP-S2SC160 1 x Duplex SC 2.0 5.0 -34.0 -9.0 36.0 1550 SMF 160 km
(100 mi)
IDS-105GPP-S2ST160 1 x Duplex ST 2.0 5.0 -34.0 -9.0 36.0 1550 SMF 160 km
(100 mi)






 Operating Temperature (Ind) = -40° C to 75° C ( -40 F to 167° F )
All Models have 5 x 10/100/1000Base-T ( RJ45 ) Connectors
 

Model

Choose your Fiber Connection from the table below
1000Base-X Duplex Fiber

Fiber
Connector

Transmit
(dBm)

Receive
(dBm)

Power
Budget
(dB)

Wavelength
(nm)

Fiber
Type

Operating
Distance

Min

Max

Min

Max

IDS-105GPP-XT No Fiber connection
IDS-105GPP-SFP-XT 1 x SFP slot (empty) Fiber specifications are dependent upon the choice of SFP used
IDS-105GPP-DSFP-XT 2 x SFP slot (empty) Fiber specifications are dependent upon the choice of SFP used
IDS-105GPP-M2SC05-XT 1 x Duplex SC -9.5 -4.0 -17.0 -3.0 7.5 850 MMF 550 m
(1,804 ft)
IDS-105GPP-M2ST05-XT 1 x Duplex ST -9.5 -4.0 -17.0 -3.0 7.5 850 MMF 550 m
(1,804 ft)
IDS-105GPP-S2SC10-XT 1 x Duplex SC -9.5 -3.0 -20.0 -3.0 10.5 1310 SMF 10 km
(6.2 mi)
IDS-105GPP-S2ST10-XT 1 x Duplex ST -9.5 -3.0 -20.0 -3.0 10.5 1310 SMF 10 km
(6.2 mi)


* 1db/km multimode 50/125 micron fiber cable


Single Fiber ( Simplex / BiDi ) Models Recommended use in pairs



Operating Temperature (Std) = 0° C to 60° C (32° F to 140° F).
All Models have 5 x 10/100/1000Base-T ( RJ45 ) Connectors

Model

Choose your Fiber Connection from the table below
1000Base-X Simplex ( BiDi ) Fiber

Fiber
Connector

Transmit
(dBm)

Receive
(dBm)

Power
Budget
(dB)

Wavelength
(nm)
TX / RX

Fiber
Type

Operating
Distance

Min

Max

Min

Max

IDS-105GPP-S1SC10U 1 x Simplex SC -9.0 -3.0 -20.0 -3.0 11.0 1310 / 1490 SMF 10 km
(6.2 mi)
IDS-105GPP-S1SC10D 1 x Simplex SC -9.0 -3.0 -20.0 -3.0 11.0 1490 / 1310 SMF 10 km
(6.2 mi)
IDS-105GPP-S1SC20U 1 x Simplex SC -8.0 -3.0 -22.0 -3.0 14.0 1310 / 1490 SMF 20 km
(12.4 mi)
IDS-105GPP-S1SC20D 1 x Simplex SC -8.0 -3.0 -22.0 -3.0 14.0 1490 / 1310 SMF 20 km
(12.4 mi)
IDS-105GPP-S1SC40U 1 x Simplex SC -3.0 2.0 -23.0 -3.0 20.0 1310 / 1490 SMF 40 km
(24.9 mi)
IDS-105GPP-S1SC40D 1 x Simplex SC -3.0 2.0 -23.0 -3.0 20.0 1490 / 1310 SMF 40 km
(25 mi)
IDS-105GPP-S1SC80U 1 x Simplex SC -2.0 3.0 -26.0 -3.0 24.0 1510 / 1590 SMF 80 km
(50 mi)
IDS-105GPP-S1SC80D 1 x Simplex SC -2.0 3.0 -26.0 -3.0 24.0 1590 / 1510 SMF 80 km
(50 mi)
IDS-105GPP-S1SC120U 1 x Simplex SC -3.0 2.0 -34.0 -9.0 31.0 1510 / 1590 SMF 120 km
(74.6 mi)
IDS-105GPP-S1SC120D 1 x Simplex SC -3.0 2.0 -34.0 -9.0 31.0 1590 / 1510 SMF 120 km
(74.6 mi)



 Operating Temperature (Ind) = -40° C to 75° C ( -40 F to 167° F )
All Models have 5 x 10/100/1000Base-T ( RJ45 ) Connectors
 

Model

Choose your Fiber Connection from the table below
1000Base-X Simplex ( BiDi ) Fiber

Fiber
Connector

Transmit
(dBm)

Receive
(dBm)

Power
Budget
(dB)

Wavelength
(nm)
TX / RX

Fiber
Type

Operating
Distance

Min

Max

Min

Max

IDS-105GPP-S1SC10U-XT 1 x Simplex SC -9.0 -3.0 -20.0 -3.0 11.0 1310 / 1490 SMF 10 km
(6.2 mi)
IDS-105GPP-S1SC10D-XT 1 x Simplex SC -9.0 -3.0 -20.0 -3.0 11.0 1490 / 1310 SMF 10 km
(6.2 mi)




 Industrial Ethernet Switch Accessories 
Panel Mount kit PM3 Brackets for attaching 30 to 40mm wide Perle IDS industrial switches inside a control panel or to a wall.
Rack Mount Kit RM4U Bracket for mounting one or more Perle DIN Rail switches in a standard 19” rack. Occupies “4U” of vertical rack space. 275 mm ( 10 inches ) deep
TRIO-PS/1AC/48DC/10 Power Supply TRIO-PS/1AC/48DC/10 Power Supply - DIN-Rail 48 VDC , 480 Watt power supply with universal 85 to 264 VAC, 30 to 56V DC output range adjustable, -25 to 70°C extended operating temperature. Power Supply Specifications.
UNO-PS/1AC/24DC/150W Power Supply UNO-PS/1AC/24DC/150W Power Supply - DIN-Rail 24 VDC , 150 Watt power supply with universal 85 to 264 VAC, -25 to 70°C extended operating temperature. Power Supply Specifications.






Kunden, die diesen Artikel gesehen haben, sahen auch
Alle Cookies akzeptieren Ablehnen Konfigurieren

Diese Website verwendet Cookies, um eine bestmögliche Erfahrung bieten zu können. Mehr erfahren.