MOXA MGate 5134 Series
1-port Modbus RTU/ASCII/TCP-to-PROFINET gateways
- Protocol conversion from Modbus to PROFINET
- Supports PROFINET IO device
- Supports Modbus RTU/ASCII/TCP client
- Flexible deployment with Ethernet cascading and dual subnet
- Embedded traffic monitoring/diagnostic information for easy troubleshooting
- Easy device configuration via a web-based console
- microSD card for configuration backup/duplication
- Supports dual redundant DC power inputs and 1 relay output
- Serial port with 2 kV isolation protection
- -40 to 75°C wide operating temperature models available
- Developed according to IEC 62443-4-2 with Secure Boot
The MGate 5134 is an industrial Ethernet gateway for converting Modbus RTU/ASCII/TCP to PROFINET network communications. To integrate existing Modbus devices onto a PROFINET network, use the MGate 5134 as a Modbus client to collect data and exchange data with the PROFINET host. All models are protected by a rugged and compact metal housing, are DIN-rail mountable, and offer built-in serial isolation. The rugged design is suitable for industrial applications such as factory automation, power, oil and gas, water and wastewater, and other process automation industries.
Easy Configuration
The MGate 5134 gateways are provided with a web console to make configuration easy without having to install an extra utility. In addition, HTTPS encryption of communication ensures higher network security. In most data-acquisition applications, configuration of devices with Modbus commands can be time-consuming and increase costs. The MGate 5134 gateways provide offline configuration via a CSV file to help complete the Modbus settings quickly. The gateways also come with a GSDML export function to enable export of these files so that they can be imported to PROFINET PLCs. The MGate gateways provide software-configurable pull high/low and termination resistor settings for RS-485 2-wire to reduce efforts by eliminating the need to open the chassis.
Easy Troubleshooting
The MGate 5134 gateways provide a variety of maintenance functions to reduce troubleshooting time and cost, including LED indicators, protocol diagnostics, traffic monitor, and tag view. These tools help you capture and check data to easily identify the root cause of issues, especially during the installation stage. The MGate gateways also come with status monitoring and fault protection functions. The status monitoring function notifies a PLC/DCS/SCADA system when a Modbus device gets disconnected or does not respond, in which case the process PLC/DCS gets the status of each end device and then issues alarms to notify operators. The fault protection function executes actions pre-defined by the user when a host gets disconnected to prevent the end devices from going offline for long periods of time.
Easy Configuration
The MGate 5134 gateways are provided with a web console to make configuration easy without having to install an extra utility. In addition, HTTPS encryption of communication ensures higher network security. In most data-acquisition applications, configuration of devices with Modbus commands can be time-consuming and increase costs. The MGate 5134 gateways provide offline configuration via a CSV file to help complete the Modbus settings quickly. The gateways also come with a GSDML export function to enable export of these files so that they can be imported to PROFINET PLCs. The MGate gateways provide software-configurable pull high/low and termination resistor settings for RS-485 2-wire to reduce efforts by eliminating the need to open the chassis.
Easy Troubleshooting
The MGate 5134 gateways provide a variety of maintenance functions to reduce troubleshooting time and cost, including LED indicators, protocol diagnostics, traffic monitor, and tag view. These tools help you capture and check data to easily identify the root cause of issues, especially during the installation stage. The MGate gateways also come with status monitoring and fault protection functions. The status monitoring function notifies a PLC/DCS/SCADA system when a Modbus device gets disconnected or does not respond, in which case the process PLC/DCS gets the status of each end device and then issues alarms to notify operators. The fault protection function executes actions pre-defined by the user when a host gets disconnected to prevent the end devices from going offline for long periods of time.
Specifications
Package Contents
Ordering Information
Accessories (sold separately)
- Ethernet Interface
- 10/100BaseT(X) Ports (RJ45 connector)
2
Auto MDI/MDI-X connection
Magnetic Isolation Protection
1.5 kV (built-in)
Ethernet Software Features
- Industrial Protocols
Modbus TCP Client, PROFINET IO Device
Configuration Options
Web Console (HTTPS), Device Search Utility (DSU)
Management
ARP, DHCP Client, DNS, HTTP, HTTPS, SMTP, SNMP Trap, SNMPv1/v2c/v3, TCP/IP, UDP
MIB
RFC1213, RFC1317
Time Management
NTP Client
Security Functions
- Authentication
Local database
Encryption
HTTPS, AES-128, AES-256, SHA-256
Security Protocols
SNMPv3
SNMPv2c Trap
HTTPS (TLS 1.3)
Serial Interface
- No. of Ports
1
Connector
DB9 male
Serial Standards
RS-232/422/485
Baudrate
300 bps to 921.6 kbps
Data Bits
7, 8
Parity
None, Even, Odd, Space, Mark
Stop Bits
1, 2
Flow Control
RTS Toggle (RS-232 only), RTS/CTS
RS-485 Data Direction Control
ADDC (automatic data direction control)
Pull High/Low Resistor for RS-485
1 kilo-ohm, 150 kilo-ohms
software configurable
Terminator for RS-485
120 ohms
software configurable
Isolation
2 kV (built-in)
Serial Signals
- RS-232
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422
Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w
Data+, Data-, GND
RS-485-4w
Tx+, Tx-, Rx+, Rx-, GND
Serial Software Features
- Industrial Protocols
Modbus RTU/ASCII Client
Modbus RTU/ASCII
- Mode
Client
Functions Supported
1, 2, 3, 4, 5, 6, 15, 16, 23
Max. No. of Server Connections
31
Max. No. of Commands
128 per serial port
Modbus TCP
- Mode
Client
Functions Supported
1, 2, 3, 4, 5, 6, 15, 16, 23
Max. No. of Server Connections
32
Max. No. of Commands
128
Total Output Data Size
2048 bytes
Total Input Data Size
2048 bytes
PROFINET
- Mode IO Device
class B
Max. No. of Master Connections
2 IO Controllers (shared devices)
Input Data Size
1440 bytes per IO Controller (total: 2880 bytes)
Output Data Size
1440 bytes per IO Controller (total: 2880 bytes)
Memory
- microSD Slot
Up to 32 GB (SD 2.0 compatible)
Power Parameters
- Input Voltage
12 to 48 VDC
Input Current
455 mA (max)
Power Connector
Spring-type Euroblock terminal
Relays
- Contact Current Rating
Resistive load: 2 A @ 30 VDC
Physical Characteristics
- Housing
Metal
IP Rating
IP30
Dimensions
25 x 90 x 129.6 mm (0.98 x 3.54 x 5.1 in)
Weight
294 g (0.65 lb)
Environmental Limits
- Operating Temperature
MGate 5134: -10 to 60°C (14 to 140°F)
MGate 5134-T: -40 to 75°C (-40 to 167°F)
Storage Temperature (package included)
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
5 to 95% (non-condensing)
Standards and Certifications
- Safety
EN 61010-2-201, UL 61010-2-201
EMC
EN 61000-6-2/-6-4
EMI
FCC Part 15B Class A
EMS
IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m
IEC 61000-4-8 PFMF
Freefall
IEC 60068-2-31
Shock
IEC 60068-2-27
Vibration
IEC 60068-2-6, IEC 60068-2-64
MTBF
- Time
1,240,821 hrs
Standards
Telcordia SR332
Package Contents
- Device
1 x MGate 5134 Series gateway
Documentation
1 x quick installation guide
1 x warranty card
Ordering Information
Model Name | No. of Serial Ports | Operating Temperature |
---|---|---|
MGate 5134 | 1 | -10 to 60°C |
MGate 5134-T | 1 | -40 to 75°C |
Accessories (sold separately)
- Connectors
- Mini DB9F-to-TB
DB9 female to terminal block connector
Wall-Mounting Kits
- WK-25
Wall-mounting kit, 2 plates, 4 screws, 25 x 43 x 2 mm
Kunden, die diesen Artikel gesehen haben, sahen auch